OsseoFuse® OneDrill System

Effective. Simplified. Less Invasive.

Angled OsseoFuse OneDrill surgical drill

OsseoFuse® is designed to simplify dental implant treatment by streamlining both the clinical workflow and the patient experience. Its OneDrill® system reduces the number of drilling steps and procedural complexity.2 High primary stability can support immediate treatment options in appropriately selected cases.2,5 By bringing key steps together into a more efficient workflow, OsseoFuse may help reduce chair time and, in suitable cases, the number of separate treatment stages.2,5,8 For selected sinus cases, SinusFuse® integrates implant placement, sinus elevation and autogenous bone management into one coordinated workflow.6

Proven and Trusted Worldwide

Backed by 18+ Years of Research

Side-by-side radiographic views of a dental implant site.

More than

300,000

implants placed worldwide

Across

8 Global

regions regulatory approvals

Over

97.28%

cumulative long-term survival 1

OneDrill®

Simpler. Faster. Less Invasive.

With fewer instruments and a simplified drilling sequence, OneDrill® is designed to be easier for clinicians to learn and navigate. Less time is spent selecting and changing drills, allowing clinicians to focus more attention on treatment planning, precise placement, and patient care.2

Side-Cutting

Freedom to Fine-Tune

Not every osteotomy begins perfectly. The side-cutting drill allows clinicians to make controlled lateral adjustments, refine positioning, and navigate challenging anatomy with greater confidence.2

Illustration of an implant aligned toward the restorative position.

Position with precision.

Guide the implant toward the ideal restorative position. Designed to support better aesthetics, bite, and long-term care.

Illustration of lateral adjustment with the OneDrill drill.

Refine the path.

Make small lateral adjustments when needed. Better positioning helps support a more natural-looking, functional result.

Illustration of selective drilling around an implant site.

Designed to preserve more bone.

Widen only where necessary. Selective cutting helps conserve healthy bone around the implant site.

Illustration of drill positioning in an extraction socket.

Adapt to anatomy.

Navigate extraction sockets, irregular bone, and limited space with greater control. Giving clinicians more flexibility in challenging cases.

Step-Interlocking

Strong Primary Stability.
Strong from day one. 2

Supplied chart showing primary, secondary and combined implant stability over time.

Step-Locking is designed to create mechanical engagement at multiple levels of the osteotomy without relying solely on generalized compression of the surrounding bone.2

For clinicians, it means greater confidence from placement through healing. For patients, it means less unnecessary bone trauma, a stable foundation, and a smoother journey toward a lasting smile.

Clinical photograph of an extraction socket between adjacent teeth.

Preserve the Natural Bone.

After a tooth is removed, the surrounding bone naturally begins to remodel. OsseoFuse is designed for high primary stability, allowing the implant to achieve secure fixation at the intended bone level.

This allows your dentist to work with the bone that is already there, without unnecessarily altering the natural bone level simply to gain implant stability.

Clinical photograph of an implant placed within an extraction socket.

Stable. And in the Right Position.

The implant is placed to achieve good initial stability while staying aligned with where the replacement tooth should naturally sit. Instead of tilting the implant simply to search for more bone, the aim is to keep it in a favorable position for the future restoration.5

This helps the replacement tooth look more natural, bite more comfortably, and function better over the long term.

Clinical photograph of a healing abutment at an implant site.

One Less Procedure to Think About.

When adequate primary stability is achieved, a healing abutment can be connected immediately. This allows the gum to begin healing around the implant from day one. In suitable cases, it can also avoid a separate procedure later to uncover the implant.8

For patients, that may mean one less surgical visit, one less local anaesthetic, fewer surgical steps, and a more comfortable treatment journey.

Clinical photograph of gum tissue surrounding a healing abutment.

Healing in the Right Position.

One week later, the gum is already beginning to heal around the implant and healing abutment. By preserving the surrounding bone, achieving good initial stability, and keeping the implant in the intended position from the start, treatment begins with a strong foundation for the replacement tooth.5

From extraction to healing, every step is designed to preserve more, intervene less, and position the implant where it can best support your new smile.

SinusFuse®

True Minimally Invasive

No malleting. No lateral window. A transcrestal approach designed to reduce surgical intervention. SinusFuse® brings sinus elevation, bone grafting, and implant placement together in one streamlined approach for appropriately selected cases.6,7

5-in-1 Treatment

Five Key Procedures. One Coordinated Surgical Visit.

For appropriately selected cases, the OsseoFuse 5-in-1 concept brings extraction, implant placement, sinus elevation when required, bone grafting and placement of a healing abutment and/or provisional restoration into one coordinated surgical appointment.8

  1. Illustration: extract the tooth.

    Extract the Tooth

    Remove the failing tooth while preserving the site for immediate Implant treatment.

  2. Illustration: lift the sinus.

    Lift the Sinus

    Elevate the sinus membrane to create the vertical space required for implant placement.

  3. Illustration: graft the bone.

    Graft the Bone

    Place graft material beneath the elevated sinus membrane to augment the implant site

  4. Illustration: place the implant.

    Place the Implant

    Position the implant within the prepared site during the same surgical visit

  5. Illustration: restore the tooth.

    Restore the Tooth

    Where primary stability and clinical conditions permit, provide an immediate provisional restoration.

One coordinated treatment visit, designed to preserve your smile, function and confidence while reducing unnecessary disruption to your everyday life.

Eat Comfortably

Enjoy greater comfort and function while you heal, when clinically suitable.

Maintain Your Smile

Avoid being left without a visible tooth where immediate restoration is suitable.

Fewer Surgical Visits

Combine key procedures into one visit, reducing the need for separate surgical appointments.

Get Back to Life

Move forward with your recovery and everyday routine.

OsseoFuse makes surgery simpler, reducing surgical intervention times, increasing patient satisfaction.

What's most amazing is that it can handle almost all complicated cases. We've only just started using it.

Dr. Celine Chang

Harvest Dental Care

I now have the ability to handle cases that used to require sinus lift surgery before implantation.

I truly admire Dr. Leon Chen’s exceptional perspectives. He has designed such simple and effective techniques that have allowed me to advance in a very short period of time. The concept of subtraction is gradually being applied in many aspects, which is fantastic.

Dr. Tyron Jones

Happiness Dental Clinic

The simplification of drilling, when placing multiple implants, has saved me some time.

Usually, when placing multiple implants, I have to keep changing burs. With OsseoFuse, skipping the switching process makes the surgical process more efficient.

Dr. Dave Walker

New Classic Dental

At the age of 79, I had planned to retire until I discovered the Osseofuse onedrill system.

I was surprised by its simplicity. Now, at 82, I'm not ready to retire anytime soon. I placed an average of over 50 implants per month.

Dr. Hsu Long-Sean

Dr. Hsu Dental Clinic

Shorter chair time and less discomfort for patients.

OsseoFuse made me realize that among the numerous dental implant brands, there is a system that can simplify complexity.

Dr. Arman Nadim

Sun Dental Clinic

The products from OsseoFuse are the best dental implants I’ve ever used.

Especially for immediate implant immediate restoration cases, as well as sinus lift surgeries. I wholeheartedly recommend OsseoFuse to fellow dentists.

Dr. Tom Boujenah

Digital Smile Dental Clinic

The design streamlines immediate implant and restoration into one single surgery.

The use of just one single drill for implant site preparation eliminates the need for multiple drill changes, significantly reducing surgical time. The OsseoFuse system design exceeded my expectations.

Dr. Paul Schneider

Master Dental Clinic

I realized that dental implantation could be so simple, so effortless.

It wasn’t until 2020, when I coincidentally came across OsseoFuse, that my eyes were truly opened. I found that the doctor I hadn’t seen in 12 years had taken the treatment techniques to an unimaginable level!

Dr. Ayoub Lahlou

Lahlou Dental Clinic

FAQ

Frequently asked questions

Straight answers about the OsseoFuse OneDrill® System, primary stability, immediate implant placement, SinusFuse, clinical evidence and practice workflow.

OneDrill® & the OsseoFuse System

Understand what makes OsseoFuse different, from its streamlined drilling protocol to the 1 Drill, 1 Platform, 1 Kit concept.

What is the OsseoFuse OneDrill® System?

The OsseoFuse OneDrill® System is designed to prepare an implant osteotomy using a single implant-matched stepped drill instead of progressing through a conventional sequence of increasingly wider drills.2

One drill incorporates the functions normally distributed across several instruments, including site initiation, guidance, progressive enlargement and depth control. That means fewer drill changes, fewer instruments to manage and a more streamlined surgical sequence.

It is part of the broader OsseoFuse philosophy: 1 Drill. 1 Platform. 1 Kit.

What does “1 Drill. 1 Platform. 1 Kit.” mean?

It is the core OsseoFuse system concept.

1 Drill means the primary osteotomy can be prepared with an implant-matched OneDrill® rather than a sequence of multiple diameter drills.2

1 Platform means OsseoFuse standardizes the restorative connection across compatible implant diameters, helping reduce the number of restorative components a practice needs to keep on hand.

1 Kit means the OsseoFuse Master Surgical Kit supports multiple OsseoFuse implant systems, including HexaPLUS, ConicalPLUS, OneBody, Element Z-40, Mini and SinusFuse.

The result is a more unified workflow with fewer drills, fewer kits and potentially less surgical and restorative inventory to purchase, sterilize, organize and train the team to use.

How is OsseoFuse different from a conventional multi-drill implant system?

Traditional implant osteotomies commonly progress through several increasingly wider drills before the implant is inserted.

OsseoFuse integrates those stages into one stepped drill matched to the intended implant dimensions. Fewer drill changes can mean a simpler surgical sequence, fewer instruments on the tray and greater workflow efficiency, particularly when multiple implants are being placed.2

The system then extends that simplification beyond drilling through shared surgical instrumentation and a simplified restorative platform.

Does using OneDrill® mean sacrificing accuracy?

No. Fewer drills does not mean less precision.

The OneDrill® incorporates progressive stepped diameters, guidance and a physical stopper for depth control. Its lateral-cutting design also provides the clinician with an ability that can be difficult once a conventional straight osteotomy has been established: intraoperative redirection of the osteotomy when correction is required.2,4

Accuracy still depends on diagnosis, planning, anatomy, positioning, surgical execution and appropriate use of guided surgery where indicated.

What happens if my drilling angle needs to be corrected?

This is one of the practical advantages of the stepped, lateral-cutting OneDrill® design.

The cutting flutes provide lateral cutting capability, allowing the clinician to redirect the osteotomy rather than being completely committed to the original trajectory once drilling has started. OsseoFuse training materials describe the system as allowing the angle to be adjusted multiple times during the procedure.2

This creates a greater degree of procedural tolerance and intraoperative correction than a purely axial drilling concept.

Can OneDrill® help reduce procedure time?

Potentially, yes.

Every drill change requires an additional instrument selection and surgical step. OneDrill® reduces repeated drill changes by integrating the conventional sequence into one stepped instrument.

That difference can become more meaningful as the number of implant sites increases. The advantage is not speed for its own sake. It is a simpler surgical workflow with fewer interruptions and fewer instruments to manage.2

Actual treatment time varies according to anatomy, case complexity, clinician experience and the procedure performed.

Primary Stability & Immediate Implant Treatment

Explore step-locking, immediate extraction cases, loading considerations and how OsseoFuse approaches primary stability without relying simply on bone compression.

How does OsseoFuse achieve high primary stability?

OsseoFuse combines its stepped osteotomy with implant geometry through a concept described as Step-Locking.

The OneDrill® creates alternating areas of prepared bone along the osteotomy. During insertion, the tapered implant body, active threads and lateral cutting features mechanically engage these areas at multiple levels.

Rather than relying simply on compressing the entire osteotomy, the objective is controlled points of engagement that help the implant lock into available bone.2

Strong primary stability can be particularly valuable in immediate extraction sites, low-density bone and other cases where obtaining mechanical stability is more challenging.

Can higher primary stability make immediate loading more achievable?

Yes, when the implant, patient, restoration and applicable regulatory indication allow it.

High primary stability is widely recognized as one of the key prerequisites when immediate or early loading is being considered. OsseoFuse's Step-Locking concept is designed to help clinicians obtain strong mechanical engagement at placement, which can expand the clinical possibilities for immediate provisionalization in appropriately selected cases.

However, primary stability alone does not determine whether an implant should be immediately loaded. Bone quality, implant position, occlusion, restorative design, patient factors and the product's Instructions for Use must also be considered.11

For example, the current U.S. FDA-cleared HexaPLUS S OneDrill Implant System under K243078 is indicated for delayed loading.10

Can OsseoFuse be used for immediate implant placement after extraction?

Yes. Immediate post-extraction placement is a well-documented application within the OsseoFuse clinical literature.

The six-year retrospective HexaPlus study included implants placed in fresh extraction sites, and subsequent OneDrill® publications describe immediate extraction and implant-placement protocols.1

The advantage of the system in these cases is the combination of a streamlined osteotomy and implant design intended to obtain primary stability even when the geometry of a fresh socket makes stabilization more demanding.2,5

Immediate placement still depends on socket anatomy, available bone, infection control, implant positioning, soft tissue conditions and clinical judgment.

Is OneDrill® the same as osseodensification?

No. The mechanical concepts are different.

Osseodensification is designed to preserve, compact and densify bone around the osteotomy rather than remove it.

OsseoFuse uses a cutting approach. Its lateral cutting features and implant side-cutting grooves shave bone rather than relying on generalized compression. The implant geometry then uses those prepared areas as part of the Step-Locking mechanism for primary stability.

That distinction matters. OsseoFuse's stability concept should not be described simply as “compressing the bone.”2

Does using only one drill create more heat?

Not inherently.

Heat generation during implant osteotomy is multifactorial. Drill design, sharpness and wear, rotational speed, applied pressure, drilling time, bone density and irrigation can all affect temperature.

The number of drills alone therefore cannot determine thermal risk.3

Clinicians should follow the prescribed OsseoFuse drilling protocol and adapt technique appropriately to the bone and clinical situation.

What happens if an implant fails to osseointegrate?

OsseoFuse incorporates contingency planning into its implant diameter sequence.

A published OsseoFuse case series describes failed implants being removed and, where the remaining anatomy permitted, replaced immediately in the original osteotomy with an implant two width sizes larger to re-establish primary stability.9

This provides the clinician with a planned rescue pathway rather than treating every failed implant as an entirely new surgical problem.

Whether immediate reimplantation is appropriate depends on the condition of the site, remaining bone, infection control and clinical judgment.

SinusFuse® & Osseotransportation

Understand how SinusFuse combines implant placement, autogenous bone management and sinus elevation in one integrated workflow.

What is SinusFuse®?

SinusFuse® is OsseoFuse's implant concept developed specifically for selected posterior maxillary sites where limited residual bone height beneath the sinus complicates conventional implant placement.

Rather than treating implant placement and sinus elevation as completely separate procedures, SinusFuse incorporates sinus-floor management and autogenous bone transportation into the implant-placement process itself.6

How does SinusFuse® work?

SinusFuse does not generate new bone during insertion.

Its reverse-helical lateral cutting grooves shave the patient's existing autogenous bone as the implant advances. Those bone particles are then transported apically through the reverse cutting grooves and collected in the implant's concave, dish-like apical reservoir.

This mechanism is known as osseotransportation.

As the implant reaches the sinus floor, its apical design is used to up-fracture the remaining thin cortical floor while the reservoir of autogenous bone contributes to elevation of the Schneiderian membrane.6

In simple terms:

shave → transport → collect → elevate

All within the implant-placement workflow.

What is osseotransportation?

Osseotransportation is the process by which SinusFuse harvests and relocates the patient's own bone during implant insertion.

The reverse-helical cutting grooves shave autogenous bone from the osteotomy and transport those particles apically into the concave reservoir of the implant.

Importantly, this occurs without removing the harvested bone from the surgical site and transferring it through the external environment. The published 5-in-1 description specifically identifies this internal harvest-and-transport process as osseotransportation.6

This reduces additional bone handling and eliminates a separate donor-site harvesting step for that autogenous material.

How is SinusFuse® different from a conventional sinus lift?

Traditional sinus augmentation may require separate instruments, separate graft handling or a lateral-window or transcrestal elevation procedure before or alongside implant placement.

SinusFuse integrates several of these functions into the implant itself.

Its reverse cutting grooves shave and transport autogenous bone, its apical reservoir retains that bone beneath the membrane, and its apical design contributes to up-fracturing the remaining sinus floor.

Because the autogenous particles are transported internally from the osteotomy to the apical region, they are not separately harvested, exposed to the external environment and then transferred back into the site.6

That reduces handling and an opportunity for external contamination. It should not be marketed as proving a lower infection rate unless clinical comparative evidence establishes that outcome.

Can SinusFuse® perforate the sinus membrane?

Membrane perforation remains a potential complication of any sinus-elevation procedure. SinusFuse does not make that risk zero.6,7

What is different is the mechanism at the apex.

The SinusFuse apical design is intended to up-fracture the final thin layer of sinus floor, rather than depend on aggressively cutting upward into the sinus membrane. At the same time, the concave apical reservoir collects autogenous bone between the implant and Schneiderian membrane.

That bone-filled interface creates a cushioning layer as the membrane is elevated, rather than presenting the membrane with only a bare advancing implant tip.6

Careful radiographic assessment, residual-bone evaluation, membrane integrity and surgical technique remain essential.

Does SinusFuse® eliminate the need for bone grafting?

Not in every case.

SinusFuse's reverse cutting grooves supply autogenous bone from the patient's own osteotomy, which is transported to the apical reservoir during implant placement.

Depending on residual bone height, defect dimensions and the treatment plan, this autogenous bone may form part of the augmentation strategy. Additional graft material may still be indicated in more demanding cases.

The advantage is therefore not “no grafting ever.” It is the ability to harvest and transport autogenous bone automatically as part of implant placement.6

Is SinusFuse® just another osteotome sinus lift?

No.

A traditional osteotome technique uses separate instruments to mechanically displace the sinus floor and elevate the membrane.

SinusFuse incorporates the elevation mechanism into the implant itself. Its reverse-helical side cuts transport autogenous bone apically, while its apical design functions as a built-in osteotome during the final portion of advancement.6

It is also not limited to cases with 4 mm or more of residual bone. OsseoFuse's clinical SOP includes a specific pathway for 2 to 4 mm of residual sinus-floor thickness. Published HSC literature also reports use in very low residual-bone situations and states that implant placement can be performed at sites with as little as 2 mm of bone.

These are advanced cases that require appropriate training, diagnosis and case selection.

Evidence, Safety & Case Selection

Review the published clinical evidence, regulatory status and the types of cases in which OsseoFuse has been used.

Is there published clinical evidence for OsseoFuse?

Yes.

A six-year retrospective multicenter report evaluated 258 OsseoFuse HexaPlus implants in 95 patients and reported a 97.28% cumulative long-term survival rate. The study included real-world cases such as fresh extraction sites and patients with active periodontal disease.1

Additional published literature describes the OneDrill® system, Step-Locking, immediate implant placement, SinusFuse, hydraulic sinus elevation, osseotransportation and immediate reimplantation protocols.2,6,9

Clinical outcomes always depend on patient, site, clinician and treatment factors, so these publications should be evaluated on their own methodology and scope.

Is OsseoFuse suitable for every dental implant patient?

No implant system is suitable for every patient.

Medical status, bone quantity and quality, anatomical limitations, periodontal condition, medications, smoking, oral hygiene, restorative requirements and other risk factors must still be assessed individually.11

What OsseoFuse can offer is a workflow with fewer drilling steps, fewer instrument changes and a design focused on obtaining primary stability. These attributes may be useful when reducing surgical complexity and chair time is desirable.

The six-year HexaPlus study is notable because its 95-patient population was medically diverse and included smokers and patients with high blood pressure, diabetes, asthma and COPD. This demonstrates documented use in a real-world medically diverse population, but it does not mean every patient with those conditions is automatically a candidate.1

Is OsseoFuse only for highly experienced implant surgeons?

No.

OneDrill® was developed to reduce the number of drilling steps, instrument changes and decisions required during site preparation. OsseoFuse also provides defined surgical protocols for different clinical situations.

Its lateral-cutting capability adds corrective freedom during osteotomy preparation, while the simplified instrument sequence reduces workflow complexity.

For clinicians earlier in their implant experience, those characteristics can make the system easier to learn and manage. OsseoFuse's current OneDrill® materials specifically describe fewer steps and fewer instruments as helping to flatten the learning curve.

That does not replace appropriate implant education or surgical competency.

Product information: OsseoFuse OneDrill® System and learning curve ↗

Is OsseoFuse FDA cleared?

Specific OsseoFuse systems have received U.S. FDA 510(k) clearance.

The OsseoFuse Dental Implant System was cleared under K131748, and the HexaPLUS S OneDrill Implant System received clearance under K243078 in October 2025.10

Clearance applies to the specific products and indications described in the applicable 510(k). It should not be interpreted as blanket clearance for every OsseoFuse product or every clinical technique.

Practice Efficiency, Training & Adoption

See how OsseoFuse can simplify instrumentation, inventory, training and everyday implant workflow.

Do I need multiple surgical kits for different OsseoFuse implant systems?

No.

The OsseoFuse Master Surgical Kit is designed to support multiple OsseoFuse implant systems within a single kit, including HexaPLUS, ConicalPLUS, OneBody, Element Z-40, Mini and SinusFuse.

That can reduce the need to purchase, store, sterilize and maintain a separate surgical kit for every implant family.

One system. One master kit. Less equipment to manage.

Product information: OsseoFuse Master Surgical Kit ↗

Can OsseoFuse reduce my implant inventory?

That is one of the main objectives of the system.

The combination of implant-matched OneDrill®, a standardized platform strategy and a Master Surgical Kit reduces duplication across drilling instruments, surgical components and restorative inventory.

For a practice, the benefit can extend beyond the purchase price of an implant. Fewer SKUs can mean simpler ordering, easier stock control, fewer instruments on the surgical tray, less sterilization complexity and easier training for the clinical team.

Product information: OsseoFuse system architecture ↗ · OneDrill® inventory advantages ↗

Will switching to OsseoFuse make restorative inventory more complicated?

The system is specifically designed to move in the opposite direction.

OsseoFuse's One Platform philosophy standardizes the restorative connection across compatible implant diameters, reducing the number of different prosthetic components a clinic may need to maintain.

Specific component compatibility should still be confirmed for the implant family and restorative component being used.

Product information: OsseoFuse platform and prosthetic compatibility ↗

Why should I consider OsseoFuse if my current implant system already works?

You should not change implant systems simply because another implant exists.

The reason to evaluate OsseoFuse is whether it can solve problems that still exist in your current workflow:

fewer drills, fewer instrument changes, high primary stability, intraoperative angle correction, an integrated sinus solution, a planned reimplantation contingency, one restorative platform strategy and one Master Surgical Kit.

Those advantages become particularly relevant when your practice is placing more implants, performing immediate cases, managing sinus cases or trying to simplify inventory and team workflow.

The question is not just:

“Does my current implant system work?”

It is:

“How much complexity do I still need in order to achieve the result?”

Is OsseoFuse more expensive than conventional implant systems?

Fixture price is only one part of the cost of an implant workflow.

A meaningful comparison should also consider drills, surgical kits, prosthetic components, inventory holding, sterilization, instrument changes, staff training and chair time.

The OsseoFuse value proposition is therefore not simply the cost of one fixture. It is the potential value of 1 Drill, 1 Platform and 1 Kit across the workflow.

Actual total cost will vary according to a clinic's purchasing structure, case mix and implant volume.

How can I start using OsseoFuse?

Start with the workflow, not just the fixture.

OsseoFuse training can cover OneDrill® selection, Step-Locking, implant placement, immediate extraction protocols, SinusFuse case selection, restorative components and case-specific SOPs.

For clinicians new to the system, supported first cases and structured training can make the transition more predictable.

READY TO EXPLORE OSSEOFUSE?

See what a simpler implant workflow can change.

One drill. One platform. One kit. Explore the clinical thinking behind OsseoFuse or speak with our team about your first case.

Keep Implant Simple.

Clinical Evidence & Disclosures

Clinical and technical statements on this website are supported, where indicated, by OsseoFuse-specific publications, independent scientific literature and applicable regulatory records. Evidence strength varies by study design. Retrospective studies, case reports, technique articles, laboratory studies and preclinical research should be interpreted within their respective limitations.

  1. A retrospective report evaluated 258 OsseoFuse® HexaPlus implants placed in 95 patients over a six-year period. Seven implants were classified as failures, corresponding to a reported cumulative long-term survival rate of 97.28%. The study was retrospective and did not include a randomized comparison with another implant system. The 97.28% figure relates specifically to the implants and patients evaluated in this study and should not be interpreted as a guaranteed outcome for all OsseoFuse treatments. [ 1 ]
  2. The OsseoFuse OneDrill® is designed to combine multiple osteotomy functions within a single implant-matched stepped drill, including site initiation, progressive enlargement and depth control. Product-specific technical literature describes how the resulting stepped osteotomy interacts with the implant's active threads and lateral cutting features to create mechanical engagement at multiple levels, a concept described as Step-Locking. The publication describes the intended design mechanism and clinical technique, but does not establish superiority over other implant systems or macrogeometries. [ 2 ]
  3. Independent laboratory studies have evaluated heat generation during single-drill and sequential osteotomy preparation. Published findings indicate that single-drill preparation does not inherently produce greater heat than conventional sequential drilling and, under some experimental conditions, may generate less heat. Thermal response remains dependent on factors including drill geometry, irrigation, bone density, drilling time and surgical technique. [ 3,4 ]
  4. Independent experimental research has investigated insertion torque, implant stability, osteotomy quality and drilling accuracy with simplified drilling protocols. One in vitro study reported higher insertion torque and implant stability quotient values for the tested single-drill protocol, while preclinical research found no significant differences in removal torque or bone-to-implant contact after healing between the tested single-drill and sequential protocols. Separate research found that single-step preparation can achieve accurate osteotomy preparation. These findings support the mechanical and biological feasibility of single-drill protocols, but are not direct clinical comparisons of OsseoFuse against other implant systems. [ 5,6,7 ]
  5. Immediate implant placement following extraction is an established clinical approach for appropriately selected cases. An independent multicenter study involving 261 implants placed in fresh extraction sockets using a single-drilling protocol reported survival rates of 98.8% for immediately loaded implants and 99% for delayed-loaded implants after a mean follow-up exceeding five years. These results relate to the implant system and protocol studied and are not OsseoFuse-specific survival figures. Immediate placement remains dependent on anatomy, available bone, infection control, implant position, primary stability, restorative considerations and patient factors. [ 8 ]
  6. The clinical development underlying the OsseoFuse sinus-treatment concept includes published research on Hydraulic Sinus Condensing (HSC). An eight-year retrospective study reported treatment of 1,100 patients receiving 1,557 implants using HSC, while a separate publication described ten-year follow-up of two clinical applications of the technique. A later OsseoFuse-specific case report describes the use of a functional sinus implant together with hydraulic sinus elevation. The HSC studies predate the current SinusFuse® implant and should not be interpreted as direct clinical trials of SinusFuse. The SinusFuse-specific publication is a case report and demonstrates a clinical application rather than comparative efficacy. [ 9,10,11 ]
  7. Independent randomized clinical evidence comparing transcrestal and lateral sinus-floor elevation reported less postoperative swelling, bruising and several measures of functional limitation following the transcrestal approach in the patients studied, although pain on the day of surgery was higher in the transcrestal group. These findings support the broader rationale for minimally invasive transcrestal approaches but are not specific evidence for SinusFuse®. Sinus membrane perforation and other complications remain possible with sinus-elevation procedures. [ 12 ]
  8. Published clinical technique literature describes the OsseoFuse 5-in-1 concept as combining tooth extraction, implant placement, sinus elevation when required, bone grafting, and placement of a healing abutment and/or provisional restoration within one coordinated surgical appointment. Suitability depends on diagnosis, anatomy, primary stability, restorative requirements and other clinical factors. The complete 5-in-1 protocol is not appropriate or achievable in every patient, and further clinical investigation is required to establish long-term outcomes for the complete protocol. [ 13 ]
  9. An OsseoFuse case-series publication describes a contingency protocol in which failed implants were removed and, where anatomy and remaining bone permitted, replaced in the original osteotomy using implants of progressively greater diameter to regain primary stability. This publication demonstrates a clinical technique and case experience and should not be interpreted as comparative evidence that the protocol produces superior reimplantation outcomes. [ 14 ]
  10. OsseoFuse dental implant systems have received U.S. FDA 510(k) clearances, including K110577 and K131748. The HexaPLUS S OneDrill Implant System received 510(k) clearance under K243078 on 10 October 2025. The FDA indications for K243078 specify one- and two-stage surgical procedures and delayed loading. Product indications, loading protocols, availability and regulatory status may differ by product and jurisdiction. The applicable Instructions for Use and local regulatory requirements take precedence over information presented on this website. FDA 510(k) clearance establishes substantial equivalence for the cleared device and indications and does not establish clinical superiority over another implant system. [ 15,16,17 ]
  11. Dental implant treatment requires professional diagnosis, appropriate case selection and adherence to the applicable Instructions for Use and surgical protocol. Immediate placement, provisionalisation, loading, sinus elevation, grafting and flapless treatment are not appropriate in every case. Healing, comfort, aesthetics, function and long-term outcomes vary according to patient, anatomical, surgical and restorative factors.

Professional information notice.

Clinical and technical information on this website is intended primarily for dental professionals. Patient-facing information is provided for general educational purposes and does not replace consultation, diagnosis or individualized treatment planning by a qualified dental professional.

References

  1. Chen L, Cha J. Osseofuse One Drill® System: A 6-Year Retrospective Follow-Up of Over 250 Implants. The Journal of Implant & Advanced Clinical Dentistry. 2017;9(6):6-15.
  2. Chen L, Chen N, Chen A, Chen A, Chen N, Chen N, Cha J. A One-Drill System for Predictable Osteotomy and Immediate Implant Placement. EC Dental Science. 2023;22(1):114-128.
  3. Gehrke SA, Bettach R, Taschieri S, Boukhris G, Corbella S, Del Fabbro M. Temperature Changes in Cortical Bone After Implant Site Preparation Using a Single Bur Versus Multiple Drilling Steps: An In Vitro Investigation. Clinical Implant Dentistry and Related Research. 2015;17(4):700-707.
  4. Frösch L, Mukaddam K, Filippi A, Zitzmann NU, Kühl S. Comparison of Heat Generation Between Guided and Conventional Implant Surgery for Single and Sequential Drilling Protocols: An In Vitro Study. Clinical Oral Implants Research. 2019;30(2):121-130.
  5. Gehrke SA, Calvo Guirado JL, Bettach R, Del Fabbro M, Pérez-Albacete Martínez C, Shibli JA. Evaluation of the Insertion Torque, Implant Stability Quotient and Drilled Hole Quality for Different Drill Design: An In Vitro Investigation. Clinical Oral Implants Research. 2018;29(6):656-662.
  6. Gehrke SA, Bettach R, Sardá Aramburú Júnior J, Prados-Frutos JC, Del Fabbro M, Shibli JA. Peri-Implant Bone Behavior After Single Drill Versus Multiple Sequence for Osteotomy Drill. BioMed Research International. 2018;2018:9756043.
  7. Marheineke N, Scherer U, Rücker M, et al. Evaluation of Accuracy in Implant Site Preparation Performed in Single- or Multi-Step Drilling Procedures. Clinical Oral Investigations. 2018;22(5):2057-2067.
  8. Bettach R, Taschieri S, Mortellaro C, Del Fabbro M. Immediate Implant Placement Into Fresh Extraction Sites Using Single-Drilling Bur and Two Loading Procedures: Follow-Up Results. Journal of Craniofacial Surgery. 2018;29(8):2135-2142.
  9. Chen L, Cha J. An 8-Year Retrospective Study: 1,100 Patients Receiving 1,557 Implants Using the Minimally Invasive Hydraulic Sinus Condensing Technique. Journal of Periodontology. 2005;76(3):482-491.
  10. Chen L, Cha J, Chen HC. Two Different Clinical Indications Using Hydraulic Sinus Condensing (HSC) Technique: Ten Years Follow-Up. Dental Implantology Update. 2009;20(5):33-38.
  11. Chen L, Cha J. Achieving Predictable Hydraulic Sinus Condensing Using an Innovative Functional Sinus Implant: A Case Report. Compendium of Continuing Education in Dentistry. 2020;41(5):278-283.
  12. Farina R, Franceschetti G, Travaglini D, et al. Morbidity Following Transcrestal and Lateral Sinus Floor Elevation: A Randomized Trial. Journal of Clinical Periodontology. 2018;45(9):1128-1139.
  13. Chen L, et al. Reducing Extraction-to-Final Restoration (EFR) Time Utilizing a 5-in-1 Technique. Oral Health.
  14. Chen L, Chen N. Immediate Reimplantation at Failed Osseointegration Sites: A Drilling and Systematically Increasing Implant Width Protocol to Ensure Primary Stability. EC Dental Science. 2023;22(5):22-35.
  15. U.S. Food and Drug Administration. K110577, OsseoFuse Dental Implant System.
  16. U.S. Food and Drug Administration. K131748, OsseoFuse Dental Implant System.
  17. U.S. Food and Drug Administration. K243078, HexaPLUS S OneDrill Implant System.